Vacuum blowers series HV have been designed for conveying air and neutral gases and are especially used in industrial high vacuum technology. With a total of 19 sizes, the blowers cover a theoretical nominal intake volume flow from 180 m³/h to 97,000 m³/h and pressure ranges 10³ mbar abs up to approx. 200 mbar abs.

hv

Model Theoretical Suction Volume (m3/h) Max. admissible
differential pressure (mbar)
Power (kW) Motor Speed  (rpm)
  50HZ 60HZ   50HZ 60HZ 50HZ 60HZ
GMa/GLa 10.0 hv 180 250 130 0,75 0,75 3000 3600
GMa/GLa 10.1 hv 250 300 140 1,10 1,10 3000 3600
GMa/GLa 10.2 hv 365 450 130 1,50 1,50 3000 3600
GMa/GLa 11.3 hv 500 600 140 2,20 2,20 3000 3600
GMa/GLa 11.4 hv 750 900 130 3,00 3,00 3000 3600
GMa/GLa 12.5 hv 1000 1200 130 4,00 4,00 3000 3600
GMa/GLa 12.6 hv 1430 1700 130 5,50 5,50 3000 3600
GMa/GLa 13.f7 hv 1700 2000 110 7,50 7,50 3000 3600
GMa/GLa 13.8 hv 2400 2900 100 11,00 11,00 3000 3600
GMa/GLb 14.9 hv 3900 4700 80 11,00 11,00 3000 3600
GMa/GLb 15.10 hv 5600 6700 80 15,00 15,00 3000 3600
GMa/GLb 15.11 hv 7500 9000 80 18,50 18,50 3000 3600
GMa/GLb 16.f13 hv 8150 9800 75 18,50 18,50 1500 1800
GMa/GLb 16.13 hv 9750 11700 75 22,00 22,00 1500 1800
GMa/GLb 17.15 hv 16000 18825 60 30,00 30,00 1500 1800

HV/BP Series (Roots blowers with bypass valve)

hv_bp

Roots vacuum pumps series HV/BP complete with bypass valve are mainly used coupled to our lubricated vacuum pumps to speed up pumping down times and to achieve vacuum level up to 0,01 mbar abs. Bypass valve allows to start the Roots pump at the same time as the backing vacuum pump, protecting the Roots pump from any operation at high pressure.

Model Pumping speed (m3/h) Ultimate pressure (mbar) Power (kW) Motor Speed (rpm) Noise level (dB(A)) Weight (kg)
  50HZ 60HZ   50HZ 60HZ 50HZ 60HZ 50HZ 60HZ 50HZ 60HZ
GMa 11.3 HV/BP 500 600 0,02 1,5 2,2 3000 3600 71 72 178 184
GMa 11.4 HV/BP 730 880 0,02 2,2 3,0 3000 3600 71 72 184 189
GMa 12.5 HV/BP 1000 1200 0,02 3,0 4,0 3000 3600 72 73 232 246
GMa 12.6 HV/BP 1400 1700 0,02 4,0 5,5 3000 3600 72 73 295 317
GMa 13.f7 HV/BP 2000 2420 0,02 5,5 7,5 3000 3600 75 76 387 410
GMa 13.8 HV/BP 2840 3420 0,02 7,5 11,0 3000 3600 75 76 513 526

CM-ATEX Series Roots Blowers

cm hv-atex

Blowers HV series and CM series (fitted with canned motor), have been approved according to 94/9/EC standards, certified for ATEX Zone 0 (internal) temperature class T3 (200 °C) and Zone 1 (external) for temperature class T4 (135 °C).

The blowers with canned drive are designed for the conveyance of air and neutral gases and are especially applied in the industrial high-vacuum technology. The blowers cover with a total of 14 size theoretical intake volume flows from 105 m³/h to 15330 m³/h and pressure ranges up to 10-5 mbar abs.

Here are some examples of the various application ranges:
– Semiconductor industry
– Micro-electronics
– Production of flat screens
– Laser technology
– Solar technology
– Helium leak indicating units
– Chemical process technology
– Foil-and glass coating
– Manufacture of melting furnace
– Evacuation of hydrogen
– And many other

Model Pumping speed (m3/h) Motor Speed (rpm)
50HZ 60HZ 50HZ 60HZ
GM/GL170CM-N 170 205 2800 3380
GM/GL250CM-N 231 279 2800 3380
GM/GL340CM-N 348 420 2800 3380
GM/GL500CM-N 470 567 2800 3380
GM/GL700CM-N 695 839 2800 3380
GM/GL1000CM-N 962 1158 2800 3380
GM/GL1400CM-N 1360 1637 2800 3380
GM/GL2000CM-N 1976 2385 2800 3380
GM/GL2800CM-N 2970 3367 2800 3380
GM/GL4000CM-N 3825 4605 2800 3380
GM/GL5500CM-N 5500 6602 2800 3380
GM/GL7500CM-N 7400 8882 2800 3380
GM/GL8000CM-N 8000 9611 2800 3380